Skip to content

Copying configuration ​

Problems copying configuration from one standalone node to another with waap config pull.

the certificate does not match the fingerprint ​

  • Cause: the fingerprint is wrong, or something else answers at that address.
  • Fix: read the fingerprint on the source again (System, Accounts and access, Management access).

401 or 403 from the source ​

  • Cause: the token is wrong, expired or revoked, or its account is not an administrator with access to every application.
  • Fix: create a suitable token on the source.

Connection refused or reset ​

  • Cause: the source's management.trusted_networks does not include the target, or a firewall is in the way.
  • Fix: add the target's address on the source.

on the other node: application not found ​

  • Cause: -apps names an application the source does not have.
  • Fix: check the names with waap config show on the source.

the configuration with the copied applications is invalid ​

  • Cause: the copied application refers to a listener or address list the target does not have.
  • Fix: add them on the target first, or copy the whole configuration.