Appearance
Copying configuration
Problems copying configuration from one standalone node to another with waap config pull.
the certificate does not match the fingerprint
- Cause: the fingerprint is wrong, or something else answers at that address.
- Fix: read the fingerprint on the source again (System, Accounts and access, Management access).
401 or 403 from the source
- Cause: the token is wrong, expired or revoked, or its account is not an administrator with access to every application.
- Fix: create a suitable token on the source.
Connection refused or reset
- Cause: the source's
management.trusted_networksdoes not include the target, or a firewall is in the way. - Fix: add the target's address on the source.
on the other node: application not found
- Cause:
-appsnames an application the source does not have. - Fix: check the names with
waap config showon the source.
the configuration with the copied applications is invalid
- Cause: the copied application refers to a listener or address list the target does not have.
- Fix: add them on the target first, or copy the whole configuration.